| Fan and Thermostat |

Enlarge |
Fan - 100 CFM fan helps keep cabinets cool in hot weather
and is thermostatically controlled by unit listed below. Is supplied with all mounting hardware.
Fan Thermostat - Used with a fan to control internal
temperature of cabinets. Can be set in 10-degree
increments with a range of 70 to 150 degrees. |
- RC Network (Electric Filter) - Part Number 122-PBN2002
- Thermostat - Part Number 503-1
- Fan & Thermostat Kit - Part Number 00100102001
|
| Heater and Heater Thermostat |

Enlarge |
Heater - Warms cabinets in cold weather to keep controls working at optimum performance. This 250W 125V heater is
used with thermostat below.
Heater Thermostat - Used with heater to control internal temperature of cabinets. |
- RC Network (Electric Filter) - Part Number 122-PBN2002
- Thermostat - Part Number 122-PNC7
|
| Cabinet Shelves |

Enlarge |
Provides additional storage within cabinets and allows for
easy installation of necessary componentry.
Please specify 24", 30", 36", or 44" |
- 24" - Part Number 122-762 Shelf
- 30" - Part Number 122-702 Shelf
- 36" - Part Number 122-704 Shelf
- 44" - Part Number 122-712 Shelf
|
| Cabinet Filter |

Enlarge |
Protects equipment within the cabinet by filtering incoming air. Should be changed twice annually to assure effectiveness.
|
| Load Switches |

Enlarge |
(NEMA) - The TAPCO solid-state relay is designed to meet NEMA specifications. Each load switch contains three individually replaceable modules enclosed
in a dust resistant metal enclosure, providing mechanical protection and excellent heat sinking for the modules.
The modules are easily accessible with a screwdriver. |
- Part Number 071-2 (Modular)
- Part Number 373-1 (Discrete)
|
| Flashers |

Enlarge |
(NEMA) - The TAPCO solid-state flasher is designed
and built to meet NEMA specifications. Each
flasher contains two individually replaceable
modules enclosed in a dust resistant metal
enclosure, providing mechanical protection and
excellent heat sinking for the modules. The modules
are easily accessible with a screwdriver.
- Part number 071-1 (Modular)
- Part Number 373-2 (Discrete)
|
| Panel Mount Flasher |

Enlarge |
TAPCO's panel mount flashers contain all flashing and load switching circuitry in a convenient to use cube style package which is small enough to fit inside the signal body. These flashers may be used for flashing two tungsten lamps, LED, or inductive loads. Single circuit operation is possible by connecting only one load, thereby providing a spare circuit should overload of the connected circuit occur.
|
| Flash Transfer
Relay |

Enlarge |
110/120VAC double pole double throw relay. Years of reliable service. Operating range -40°
to 84° C.
|
| Mercury Relay
Switch |

Enlarge |
The BF (normally open)
30 AMP Mercury Relay
Switch, features long-life contacts
which provide low, stable contact resistance. Screw terminals are included for both load and control connections. The top wiring style of the load terminals allows efficient use of available panel space.
|
| Conflict Signal Monitors |
SSM-E

Enlarge
SSM-6E
|
SSM-E Series. The SSM-E Series Signal Monitors exceed all the requirements set forth in the NEMA Standard TS-1-1994, Part 6. These units are intended to provide enhanced conflict and voltage monitoring for traffic controller assemblies with additional capabilities for broader fault coverage.
- SSM-6E 6 channel - Part Number 395-SSM6E
- SSM-12E 12 channel - Part Number 395-SSM12E
SSM-LEC Series. The SSM-LEC series Signal Monitors
exceed all the requirements set forth in the NEMA Standard
TS-1-1994, Part 6. These units are intended to provide enhanced
conflict and voltage monitoring for traffic controller assemblies
with additional capabilities for broader fault coverage and
diagnostic troubleshooting. These units include a Full
Intersection Liquid Crystal Display (LCD) along with an RS232
port which is used to communicate with a Personal Computer
using EDI EComm software. Monitor status, event logs, and
Signal Sequence History logs are stored in nonvolatile memory
for diagnostic and archival purposes.
- SSM-6LEC 6 channel - Part Number 395-2
- SSM-12LEC 12 channel - Part Number 395-1
|

Enlarge
SSM-12LEC
|
| The MMU-16LE Smart Monitor™ |

Enlarge |
Upgrade your NEMA TS-1 cabinet to operate with the safety and diagnostic capabilities of a TS-2 mmu without cabinet wiring changes
The MMU-16LE Smart Monitor™, includes a built-in Setup Wizard to quickly and accurately configure the monitor parameters simply by answering a short series of questions related to the intersection geometry and cabinet wiring. The “built-in” context sensitive HELP System and Diagnostic Wizard then automatically pinpoint fault signals, thus providing technicians with an unprecedented amount of assistance and data feedback quickly with a push of the Help button. The MMU-16LE Smart Monitor™ also includes a “built-in” version of EDI's ECom™ software which displays signal voltages, data logs and vital cabinet information displayed directly on the MMU-16LE Smart Monitor™ front panel display.
- MMU-16LE - Part Number 395-016LE
|
| Pedestrian Pushbutton OPTO Isolator |

Enlarge |
TAPCO made 4-channel optical interface for use
with pedestrian pushbuttons.
|
| Video Surge Suppression CX06-M |

Enlarge |
The CX06-M Surge Protective Device (SPD) is single Coax SPD implementing three-stage hybrid technology. The SPD addresses over voltage transients with a primary gas discharge tube (GDT), and secondary silicon avalanche diode (SAD) components. Over-current protection, e.g. sneak and fault currents, are mitigated with solid-state resettable fuses PTCs. The CX06-M is designed in accordance with NFPA 780 (2004 edition) requirements, with up to 20kA of surge current capability.
|
| Street Light Breaker |

Enlarge |
20 Amp Breaker - Provides protection to electrical components when street lighting is installed within the cabinet. Includes mounting bracket.
|
| Traffic Signaling Surge Suppression
PC 642 Series |

Enlarge |
Traffic Signaling Surge Suppression
PC 642 Series— Data/Signal Modular 2-Pair
The PC642 Series surge suppressor is a dual-pair (4-wire) module implementing three-stage hybrid technology. This module addresses over voltage transients with gas tubes and silicon avalanche components. In addition, sneak and fault currents are mitigated with resettable fuses (PTCs). The PTCs increase resistance by several orders of magnitude when overcurrents exceed safe levels. normal state resumes when overcurrents are removed. The ability to self-restore in this manner significantly increases suppressor performance and survivability. |
The PC642 card edge module is gold-plated, double-sided and is designed to mate with the PCB1B gold-plated female terminal connector. When snapped together, the data circuits “pass through” the protector in a serial fashion from the four “Field Side” terminals to the four “Electronics Side” terminals. Terminals 1 or 10 of the PCB1B must be attached to Building Approved Ground.
- Part Number 221-3 Suppressor
- Part 221-4 (base for above)
|
| Traffic Signaling Surge Suppression SRA64 Series |

Enlarge |
The SRA64 Series surge suppressor is a single-pair cube implementing three-stage hybrid technology. This cube addresses over voltage transients with gas tubes and silicon avalanche components. In addition, sneak and fault currents are mitigated with resettable fuses (PTCs). The PTCs increase resistance by several orders of magnitude when overcurrents exceed safe levels. normal state resumes when overcurrents are removed. The ability to self-restore in this manner significantly increases suppressor performance and survivability. |
The standard SRA64 second-stage clamps are placed from each signal line-to-ground. In certain cases, where ground potentials vary from site-to-site, a line-to-line only second-stage clamp may be preferred. This variation is specified by a suffix “D” on the part number. In other cases, line-to-line and line-to-ground second-stage clamps may be preferred. This variation uses an “X” suffix on the part number.
|
| SPA-100T Lightning Arrestor |

Enlarge |
SPA-100T Lightning Arrestor provides EMI/RFI filtering and transient voltage suppression to protect vulnerable AC power lines.
|
Features
- No Follow Current
- 5 Nanosecond Response Time
- Automatic Recovery
- 120 VAC, 60 Ampere Service
- Flame-retardant Epoxy Encapsulated
|
| AC Power Line Filter |

Enlarge |
Power line filter complies with ISO-9001 and UL 1283 requirements. Made of high impact plastic with epoxy encapsulation assures long life and dust/water resistant. This 120VAC, Single-Phase 2 wire (line and neutral) filter is rated at 60 amperes and measures just 3.9" x 4.4" x 1.6".
|
Nominal Operating Voltage..... 120VAC
Operating Voltage Range........ 120±25%
Operating Frequency Range.... 47-63 Hz
Connection Type...................... 1/4-20 Studs
Amperes...................................60 Amperes
Phase Configuration ................ Single Phase 2 wire
(Line and Neutral)
Size..........................................3.9 in. x 4.4 in. x 1.6 in.
Weight......................................2 lbs.
Maximum Continuous
Operating Voltage (MCOV)....240VAC Load Surge
Current Rating |
| LM-302T Loop Vehicle Detector |

Enlarge |
This detector is a shelf mounted NEMA TS-1 Type with two channels and 15 levels of sensitivity. It includes 4 loop frequencies, 3 modes of operation and
delay/extension timing. Solid state
outputs are optional.
|
For additional Loop Detectors see Section 4 “Vehicle Detection”. |
| Loop Detector Harness |

Enlarge |
Eleven pin loop detector harness for use with NEMA loop detectors.
|
| Varistor |

Enlarge |
Provides line filter protection
in cabinets.
|
| Collar |

Enlarge |
Provides quick, secure cabinet mounting to poles 4 to 4.5 inches in diameter. Cast in lightweight aluminum, the collar is ready to paint and is shipped with all mounting hardware.
|
| Power Supply, Wall Transformer |

Enlarge |
DC Power supply
Input: 120VAC/60Hz
Output: Unregulated 12VDC@100mA
DC Connector: 2.5mm ultra-miniature phone plug.
Size: 2.2 x 1.7 x 1.5 inches with 5.6 feet of cable.
|
| Loading Resistor |

Enlarge |
1 K 25 watt loading resistor. Attaches easily with two mounting screws.
|
| Converter |

Enlarge |
The 485TBLED converts unbalanced, full-duplex RS-232 signals to balanced, full or half-duplex RS-422 or RS-485 signals. RS-485 is an enhanced version of the RS-422 Standard. It allows multiple drivers and receivers on a two-wire or four-wire system.
|
| Police Lock & Key |

Enlarge |
Secures cabinet from intruders and opens with universal “police door key”. Lock and key are sold separately.
- Lock - Part Number 290-1012
- Key - Part Number 122-PAK9
|
| Lock Assembly |

Enlarge |
As above but with a typical “civilian” key and dead bolt. Keys are easily replaced or duplicated when necessary. Key and lock assembly sold separately.
- Lock - Part Number 122-EL142
- Key - Part Number 122-PAK1
|
| Print Pouch |

Enlarge |
Convenient, weather-tight storage for all pertinent prints and related documents. Hangs inside door of any cabinet for easy reference.
|
| Auto Hand Cord |

Enlarge |
For police/official use. Controls intersection by hand for temporary or occasional needs. Quick and easy installation with two wire hook-up. (Requires Auto/Hand switch.)
|
TRAFFIC AND PARKING CONTROL CO., INC.
5100 W. BROWN DEER ROAD, BROWN DEER WI
PHONE: 262-814-7000 FAX:414-354-5480 TOLL FREE: 1-800-236-0112
TOLL FREE FAX: 1-800-444-0331
Copyright © 2010
TAPCO |